Vaillant F75 means the boiler did not see the pressure rise it expects when the pump starts, so it has locked out as a safety measure. The most common causes are a faulty pump or a faulty water pressure sensor, but low pressure, air in the boiler, a failed expansion vessel or a wiring fault can trigger the same code. A few safe checks can narrow it down, and anything inside the boiler casing is a job for a Gas Safe registered engineer.
| What it means | What to do first | Who is needed |
|---|---|---|
| No pressure rise was detected when the pump started | Check the gauge with the system cold and top up if it is low | A Gas Safe registered engineer if F75 returns |
| Most often a pump or pressure sensor fault | Reset once and note whether the fault comes straight back | Testing of the pump, sensor and wiring |
| Can also be low pressure, air or the expansion vessel | Do not open the casing or keep resetting | Diagnosis before any part is replaced |
What Does F75 Mean?
Inside the boiler, the pump pushes heated water around the radiators and pipework, and a small sensor reads the water pressure in the sealed system and reports it to the control board. Each time the pump starts, the boiler expects to see a short, measurable rise in that reading. Vaillant describes F75 as the pressure change being too low when the pump starts up. When that rise does not appear, the boiler locks out instead of running with a fault it cannot identify.
F75 is about what happens at the moment the pump starts, which is different from a low reading sitting on the gauge. That is why topping up the pressure on its own will not clear the code for long if the pump or sensor is at fault. On most displays it shows as F.75, with a dot, and it appears on Vaillant ecoTEC and ecoFIT boilers among others. Check the fault code list in your own boiler’s manual to confirm it for your model.
Common Causes
Vaillant lists several possible causes for F75. Some can be ruled out at home and others need testing with the boiler open.
| Cause | Typical sign |
|---|---|
| Faulty pump | Poor circulation, with radiators slow to heat or the fault returning soon after a reset |
| Faulty water pressure sensor | The gauge reads normally but F75 keeps coming back |
| Low system pressure or too little water | The gauge reads below 1 bar with the system cold |
| Air in the boiler or system | Gurgling noises, or radiators cold at the top |
| Faulty expansion vessel | Pressure climbs high when the heating runs, then falls well below normal once it cools |
| Wiring fault | The fault comes and goes with no clear pattern |
| Sludge or debris around the sensor | An older system, or one that has not been treated with inhibitor |
A pump that sounds normal is not automatically fine. A worn pump can still run while failing to move enough water, and many modern pumps are quiet enough that you will hear very little from them even when they work well. That is why an engineer tests flow and pressure directly instead of relying on noise.
F75 vs F73
F75 and F73 both involve the pressure sensor, but they check different things. F73 means the sensor’s signal is too weak, which can be caused by low pressure or by a fault in the sensor, its cable, its plug or its earth connection. With F75, the sensor’s signal can be within range, but the boiler does not see the pressure change it expects when the pump starts. Our guide to the Vaillant F73 fault code explains that code in full.
| Code | What it checks | Typical cause |
|---|---|---|
| F73 | Whether the pressure sensor’s signal is strong enough | Low pressure, or a sensor, wiring or connection fault |
| F75 | Whether pressure rises as expected when the pump starts | Pump or sensor fault, low pressure, air or the expansion vessel |
If your boiler fires but shows a code linked to temperature instead, our guide to the Vaillant F83 fault code covers that fault, which is also often caused by low water or poor circulation.
What You Can Safely Check Yourself
- Reset the boiler once, following the instructions in your manual, and note whether F75 returns straight away or after a delay.
- Check the pressure gauge with the system cold. Vaillant gives the normal cold pressure as 1 to 1.5 bar on most models, but check the figure in your handbook.
- If the pressure is low, top up slowly through the filling loop, watching the gauge so you do not overfill, then close both valves fully. If your loop is the removable type, disconnect it.
- If any radiators are cold at the top, bleed them, then check the pressure again, because bleeding lets water out of the system.
- Turn the heating on, or open a hot tap if you have a combi, and listen near the boiler. You may hear or feel a faint hum from the pump, though silence alone does not prove a fault.
Do not open the boiler casing, do not bypass the pressure sensor or any other safety device, and do not keep resetting the boiler. A reset is a check, not a repair, and repeated resets can hide a fault that is slowly getting worse.
When to Call a Gas Safe Engineer
If F75 comes straight back after a reset, the pressure keeps dropping, or the checks above make no difference, book an engineer. Replacing a pump, a pressure sensor or an expansion vessel means opening the casing of a gas appliance, and only a Gas Safe registered engineer can legally do that work. Prosecutions do happen. In one 2026 case published on press.hse.gov.uk, an unregistered installer received a suspended prison sentence after moving a boiler and flue in a way that put the household at risk of carbon monoxide.
An engineer dealing with F75 will usually check the system pressure and the expansion vessel charge, test the pump’s performance, compare the sensor’s reading against a separate gauge and inspect the wiring between them before deciding what needs replacing. It helps to tell them what you have already found: the cold pressure reading, whether a reset cleared the fault even briefly, and whether you heard the pump. Our boiler repair in London engineers carry out these checks before any part is changed.
Is Your Vaillant Still Under Guarantee?
If your boiler is still within its Vaillant guarantee, check your paperwork before you book a repair. A failed pump, pressure sensor or expansion vessel is a fault with a part of the boiler, so it may be covered. Low pressure or air in the heating system is not a fault with the boiler itself, and Vaillant may charge for a visit when the problem turns out not to be with the product. Vaillant’s longer guarantees also usually depend on the boiler being registered after installation, so confirm the registration if you are not sure.
How Much Does an F75 Repair Cost?
There is no single price for an F75 repair, because the cost depends on which part has failed. A pressure top-up or a radiator bleed costs nothing. A pressure sensor is usually a quicker and cheaper job than replacing a pump, and an expansion vessel can take longer again depending on where it sits in the boiler. An engineer can only give an accurate figure once they have tested the system.
BeFix charges £95 an hour between 7am and 5pm, £125 an hour between 5pm and 9pm, and £160 an hour between 9pm and 7am, all plus VAT, with no call-out fee. Any parts are costed separately and confirmed once the fault has been diagnosed.
How to Help Prevent F75
Check the pressure gauge every few weeks so you notice a slow drop before it causes a lockout. An annual service gives an engineer the chance to spot a pump starting to wear, an expansion vessel losing its charge or a sensor drifting out of range. A magnetic system filter and the right level of inhibitor in the water slow down the sludge and corrosion that can affect the pump and sensor over time.
If F75 keeps coming back, BeFix (Gas Safe 967796) repairs boilers across London. Call 020 8058 4241 to book an engineer.
Frequently Asked Questions
What does F75 mean?
F75 means your Vaillant boiler did not see the pressure rise it expects when the pump starts. The boiler has locked out as a safety measure. The most common causes are a faulty pump or pressure sensor, but low pressure, air in the system, a failed expansion vessel or a wiring fault can also trigger it.
Can I reset the boiler myself?
Yes, a single reset is safe to try. If F75 comes straight back, or returns within a day, resetting again will not fix the cause. Treat one reset as a check, since repeated resets can hide a fault that is getting worse.
Is F75 a pump or a pressure sensor fault?
It can be either, and the code alone does not tell you which. Low pressure, air or a faulty expansion vessel can also cause it. An engineer needs to test the pump, the sensor and the system pressure in turn to be sure.
The pump sounds fine but F75 keeps coming back. Is it the sensor?
Not necessarily. A pump can run and sound normal while still failing to move enough water, so it is not ruled out by the noise alone. An engineer should test the pump’s output and compare the sensor’s reading with the real system pressure before any part is replaced, so you do not pay for a part you did not need.
Is F75 the same as F73?
No. F73 means the pressure sensor’s signal is too weak, which can be low pressure or a sensor or wiring fault. With F75 the sensor’s signal can look normal, but the boiler does not see the pressure change it expects when the pump starts.
Can sludge cause F75?
Yes. Sludge and debris can build up around the pressure sensor or restrict flow through the pump, so the boiler does not pick up the pressure change it should. Cleaning the system can help in those cases, but an engineer should confirm sludge is the cause before recommending a power flush.
Is it safe to keep using the boiler?
The boiler will not run while F75 is showing, because the lockout is a safety feature. If it clears after a reset but keeps returning, book an engineer instead of resetting it again, since the fault can leave you without heating or hot water without warning.